text.skipToContent text.skipToNavigation

TissueLyser II

For medium- to high-throughput sample disruption for molecular analysis
  • Convenient and secure disruption process
  • Adapter sets optimized for high-throughput disruption
  • Wide range of accessories available
  • Reproducible results with difficult-to-lyse tissues
  • Front-end solution for QIAGEN automation

The TissueLyser II simultaneously disrupts multiple biological samples through high-speed shaking in plastic tubes with stainless steel, tungsten carbide, or glass beads. Using the appropriate adapter set, up to 48 or 192 samples can be processed at the same time. Alternatively, a grinding jar set can be used to process large samples. A range of beads, bead dispensers, and collection microtubes and caps are also available. All accessories for the TissueLyser II, including adapter sets, are also compatible with the TissueLyser (no longer available).

Cat No./ID: 9244420
TissueLyzer II, Basic Agreement, no PM
€633.00
Configure
1 year coverage of shipping, labor, and spare parts. The instrument is repaired in a regional repair center with a turnaround time of 7-10 working days. The agreement does not include a preventive maintenance/inspection visit.
Features
Specifications
Disruption principle High-speed shaking of samples in 1.2 ml collection tubes or 2 ml microcentrifuge tubes with stainless steel or glass beads
Features Convenient and secure disruption process. Adapter sets optimized for high-throughput disruption. Wide range of accessories available (e.g.,grinding jar set to process large samples). Reproducible results with difficult-to-lyse tissues. Front-end solution for QIAGEN automation.
Kits compatible with instrument All kits for purifying RNA/DNA/Protein
Protocol/main application on this intrument Sample preparation/sample disruption
Technical data 100–120/220–240 V, 50/60Hz; variable speeds from 3 to 30 Hz (180–1800 oscillations/minute)
Technology Bead Mill
Throughput 2 x 96 collection microtubes (1.2 ml) or 2 x 24 microcentrifuge tubes (2ml)
Typical run time 15 sec - 2 x 3 minutes at 15–30 Hz

You are not authorized to download the resource

Kit Handbooks (1)
For high-throughput disruption of biological samples
Show details
Supplementary Protocols (8)
fragment fix placeholder

Customers who bought these products also bought

  • Cat No./ID: 9241768
    /be/products//instruments-and-automation/nucleic-acid-purification/qiacube-ht/

    QIAxtractor/QIAcube HT, Basic Agreement

    1 year coverage of travel, labor, and spare parts. The instrument is repaired at the customer site with an onsite response time of 5 working days. The agreement includes a preventive maintenance/inspection visit.
    €3,554.00
  • Cat No./ID: 9241763
    /be/products//instruments-and-automation/instrument-services/warranty-extension/

    QIAgility, Full Agreement

    1 year coverage of travel, labor, and spare parts. The instrument is repaired at the customer site with an onsite response time of 48 hours. The agreement includes a preventive maintenance/inspection visit.
    €3,594.00
  • Cat No./ID: 9242700
    /be/products//instruments-and-automation/instrument-services/warranty-extension/

    QIAcube, Full Agreement

    1 year coverage of travel, labor, and spare parts. The instrument is repaired at the customer site with an onsite response time of 48 hours. The agreement includes a preventive maintenance/inspection visit.
    €3,195.00
  • Cat No./ID: 9243310
    /be/products//discovery-and-translational-research/epigenetics/dna-methylation/bisulfite-conversion-assays/rotor-gene-q/

    RGQ, Basic Agreement, no PM

    1 year coverage of shipping, labor, and spare parts. The instrument is repaired in a regional repair center with a turnaround time of 7-10 working days. The agreement does not include a preventive maintenance/inspection visit. 
    €1,785.00
  • Cat No./ID: 9241762
    /be/products//instruments-and-automation/pcr-setup-liquid-handling/qiagility/

    QIAgility, Basic Agreement

    1 year coverage of travel, labor, and spare parts. The instrument is repaired at the customer site with an onsite response time of 5 working days. The agreement includes a preventive maintenance/inspection visit.
    €2,702.00
  • Cat No./ID: 9241769
    /be/products//instruments-and-automation/nucleic-acid-purification/qiacube-ht/

    QIAxtractor/QIAcube HT, Full Agreement

    1 year coverage of travel, labor, and spare parts. The instrument is repaired at the customer site with an onsite response time of 48 hours. The agreement includes a preventive maintenance/inspection visit.
    €4,424.00
  • Cat No./ID: 9237721
    /be/products//instruments-and-automation/instrument-services/warranty-extension/

    EZ1, Full Agreement

    1 year coverage of travel, labor, and spare parts. The instrument is repaired at the customer site with an onsite response time of 48 hours. The agreement includes a preventive maintenance/inspection visit. 